NEW TRAQC-7 PC process calibrator
"On the right TRAQC with the new unique pressure calibrator"
The Traqc-7 PC will make your job easier!
- All functionality in óne compact and robust instrument
- Pressure generation from 0 to 10 bar in 10 seconds

- Clear and large display with all required information
The Traqc-7 PC, a calibrator you can rely on!
- Developed by calibration engineers for calibration engineers
- Incorporating 50 years of know-how and experience
- Proven reputation
The Traqc-7 PC, easy and fast to use!
- Only 3 function keys and 4 navigation keys
- Ergonomic integrated handpump
- Straight forward and logic menu structure

The Traqc-7 PC, do precisely what you require!
- 0,02% FS
- Pressure measurement, generation,
- signal measurement and loop calibration
- Vacuum and pressure up to 20 barg
Please contact Tradinco for further information on prices, delivery dates and other information.
Documentation
Brochure - Tradinco Quality Calibrator English
The Traqc-7PC is fully developed by Tradinco Instruments, in close co-operation with our customers. In this new standard for the industry, our knowledge, knowhow and nearly 50 years experience are combined. Our development engineers are, apart from being mechanical, electronic or software engineers, calibration specialists. They have been out there in the field and know what it is all about. Your instrument must be 100% reliable, the quality must be excellent, you even do not need to read the manual to use it and it must be rugged and robust. You want it to be there, capable of what it is intended to be used for, nothing less and nothing more!
|
|
Read more...
|
|
|
9196 High Pressure Calibrator |
|
|
|
Designed and manufactured by Tradinco
High accuracy, ± 0.05% F.S. (± 0.04%R optional)
Up to 200 bar refillable built-in pressure bottles
SS316 high pressure tubing and fittings
Mains or battery powered, built-in charger
Suitable for use with oxygen systems (options)
Interactive calibration routines, data entry and storage capability (RS232 required)
Multi-language graphic display with backlight
Pressure switch test with switch
Data sheet 29.69 Kb
|
|
Read more...
|
|
Designed and manufactured by Tradinco
Accuracy ± 0,5% F.S. (0.25% F.S. option)
Up to 200 bar refillable built-in pressure volume
SS 316 high pressure tubing and fittings
Low consumption of air or nitrogen
Separate analogue monitor gauges for bottle and regulated pressure
Suitable for use with oxygen systems (option)
Overpressure protection
Data sheet 230.84 Kb
|
|
Read more...
|
|
Designed and manufactured by Tradinco
Ranges –1 to 0 through 1000 bar
High accuracy, ± 0.05% F.S. (± 0.04%R optional)
Many pneumatic configurations
Watertight protective case
Simultaneous pressure and electrical readout pf pressure, mA, Volt, temperature
Dual power supply, mains/battery
Pressure switch test function
Easy access to battery compartment
Data sheet 39.03 Kb
|
|
Read more...
|
|
|
7304 Analog Pressure Calibrator |
|
|
|
Designed and manufactured by Tradinco
Ranges up to 10 bar
High accuracy ± 0.5% F.S. ( ± 0.25% F.S. optional)
Gauge, Analog, protected against overpressure
Very fine adjustment with precise pressure regulator
Pneumatic switch for leaktest
Robust metal case
Custom designs available
Data sheet 76 Kb
|
|
|
NOW Intrinsically safe! A Modular platform for calibration of electrical, temperature and pressure calibrator, including pressure generation - Modular concept for great flexibility
- Ergonomic
- ATEX and IEC approval
- High accuracy
- Easy to use, with video quality touch screen
- Multiple pressure sensors
- Measure, source and simulate mA, mV, V, ohms,
 - Frequency, RTDs and thermocouples
- Advanced pressure generatation up to 1000 bar
- Hart
- Documenting / AutoCal compatible
dpi620 & is 1.22 Mb |
|
Read more...
|
|
|
DPI 610/615 Pressure Calibrator |
|
|
|
Ranges from 0 to 2.5 mbar through 700 bar
Accuracy ± 0.025% F.S.
With integrated pneumatic or hydraulic handpump
Dual readout
4 to 20 mA loop test facility
Data storage with RS232 interface
Intrinsically safe and fully documenting versions available
Data sheet 2.97 Mb
|
|
Read more...
|
| |
|
|
DPI 800 Pressure Indicator |
|
|
|
Ranges 0 to 70 mbar through 700 bar
Accuracy ± 0,05% to 0,01% F.S.
Robust and weatherproof
Leak test, tare, max/min/avg, alarm and filter
mA, switch test and 24V loop power
One handed operation
Plug & play connector for IDOS universal pressure modules
Data sheet 62.59 Kb
|
|
Read more...
|
|
|
DPI 705 Pressure Indicator |
|
|
|
Ranges 0 to 70 mbar through 700 bar
± 0,1% F.S. accuracy
Rugged, lightweight handheld design
Leak test, tare, max-min and filter
Intrinsically safe version
Pneumatic and hydraulic test kits
Data sheet 829.39 Kb
|
|
Read more...
|
|
|
PM Series Pressure Indicators |
|
|
|
Ranges –0.8 to 10 bar through 1200 bar
Accuracy ± 0.03% F.S.
Auto range and peak-hold function
Stainless steel and/or hastelloy C wetted parts
RS232 interface
Can directly be mounted on a wide range of handpumps
Intrinsically safe, ATEX
Data sheet pm305-310l-310h-270603 1015.66 Kb
|
|
Read more...
|
|
|
DPI 104 Pressure Indicator |
|
|
|
Ranges 0 to 0.7 bar through 1400 bar
Accuracy 0,05% F.S.
Min/Max, Tare, Alarm
Switch test
0-5 VDC out
20 segment bar graph
also available in an intrinsically safe version
Test kit including handpump, test hose, case & accessories available
Data sheet 1.28 Mb
|
|
Read more...
|
|
Low cost full documenting software
Use with 2096,3096 or 9196 calibrators
Communication through RS232
Up & downloading calibration data and procedures
Suitable for Windows95/98/NT4/2000/XP
Link to Full size version Autocal®
|
|
|
IDOS Universal Module for DPI 800 |
|
|
|
Ranges 0 to 25 mbar through 700 bar
Accuracy ± 0.05% to ± 0.01% F.S.
Robust and weatherproof
Fully interchangeable, no set-up
Impact resistant elastomer protected
Data sheet 65.15 Kb
|
|
Read more...
|
|
|
Fluke 700 series Pressure Modules |
|
|
|
For Fluke 7XX series
Ranges from 2,5 mbar up to 700 bar
Gauge, differential dual (compound), absolute, and vacuum modules
Accuracy performances from 0°C to 50°C
Pressure readings updated twice per second
Uncertainty 0.025%
Available as intrinsically safe version (Atex)
Data sheet 89.26 Kb
|
|
|